Assessment Year | 2005 |
---|---|
Principal Product | corrugated fiberboard |
NAICS | 326191: Plastics Plumbing Fixture Manufacturing |
SIC | 3088: Plastics Plumbing Fixtures |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
125,000
ft2
|
Annual Production | 900,000,000
pieces
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $608,321 | 14,322,685 |
kWh
|
$0.042 |
Electricity Demand | $82,373 | 10,187 |
kW-mo/yr
|
$8.09 |
Natural Gas | $286,137 | 50,374 |
MMBtu
|
$5.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $82,445 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $56,892 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1221: Replace obsolete burners with more efficient ones | $10,212 | $3,850 | - | - |
$10,212
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,194 | $360 |
$4,631
38,355
kWh
|
$563
-
kW-mo/yr
|
- | - | - | |
03 | 2.6218: Turn off equipment when not in use | $980 | $76 |
$980
23,060
kWh
|
- | - | - | - | |
04 | 2.2126: Lower operating pressure of condenser (steam) | $593 | - | - | - |
$593
-
MMBtu
|
- | - | |
05 | 2.2135: Repair and eliminate steam leaks | $550 | $1,050 | - | - |
$550
-
MMBtu
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,023 | $37,287 |
$9,921
278,678
kWh
|
$4,102
-
kW-mo/yr
|
- | - | - | |
07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $13,768 | $18,500 | - | - | - |
$13,768
-
lb
|
- | |
08 | 4.211: Consider use / purchase of bulk materials where possible | $37,125 | $52,500 | - | - | - | - | $37,125 | |
TOTAL RECOMMENDED | $82,445 | $113,623 |
$15,532
340,093
kWh
|
$4,665
-
kW-mo/yr
|
$11,355
-
MMBtu
|
$13,768
-
lb
|
$37,125 | ||
TOTAL IMPLEMENTED | $56,892 | $91,197 |
$14,552
317,033
kWh
|
$4,665
-
kW-mo/yr
|
$550
-
MMBtu
|
- | $37,125 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs