Assessment Year | 2004 |
---|---|
Principal Product | food service disposable plastic containers |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
180,000
ft2
|
Annual Production | 1,600,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,164,702 | 11,482,180 |
kWh
|
$0.10 |
Electricity Demand | $322,278 | 27,334 |
kW-mo/yr
|
$11.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $983,901 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,871 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $820,692 | $1,776,190 | n/a |
$857,528
8,456,885
kWh
|
$144,168
-
kW-mo/yr
|
$(-54,151.0)
-
MMBtu
|
- | $(-126,853.0) |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $57,650 | $36,750 | n/a |
$49,586
489,010
kWh
|
$8,064
-
kW-mo/yr
|
- | - | - |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $19,672 | - |
$19,672
194,000
kWh
|
- | - | - | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,107 | $10,200 |
$13,107
129,259
kWh
|
- | - | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,768 | $28,000 | n/a |
$10,768
106,193
kWh
|
- | - | - | - |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,493 | $7,900 |
$6,493
64,037
kWh
|
- | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,377 | $360 |
$4,638
45,748
kWh
|
$739
-
kW-mo/yr
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $37,494 | $49,732 |
$32,472
310,233
kWh
|
$5,022
-
kW-mo/yr
|
- | - | - | |
09 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $12,648 | $18,500 | - | - | - |
$12,648
-
lb
|
- | |
TOTAL RECOMMENDED | $983,901 | $1,927,632 |
$994,264
9,795,365
kWh
|
$157,993
-
kW-mo/yr
|
$(-54,151.0)
-
MMBtu
|
$12,648
-
lb
|
$(-126,853.0) | ||
TOTAL IMPLEMENTED | $42,871 | $50,092 |
$37,110
355,981
kWh
|
$5,761
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs