| Assessment Year | 2004 |
|---|---|
| Principal Product | CDs and DVDs |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
60,000
ft2
|
| Annual Production | 28,000,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $183,394 | 1,956,180 |
kWh
|
$0.094 |
| Electricity Demand | $66,418 | 4,353 |
kW-mo/yr
|
$15.26 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $96,166 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $12,921 | $12,655 |
$8,816
93,985
kWh
|
$4,105
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $1,682 | $2,600 |
$995
10,612
kWh
|
$687
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,371 | $747 |
$1,371
14,622
kWh
|
- | - | - | - | |
| 04 | 2.7134: Use photocell controls | $1,538 | $1,720 |
$1,538
9,715
kWh
|
- | - | - | - | |
| 05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $5,553 | $18,500 | - | - |
$5,553
-
lb
|
- | - | |
| 06 | 4.211: Consider use / purchase of bulk materials where possible | $70,166 | $43,083 | - | - | - | $70,166 | - | |
| 07 | 4.441: Install automatic packing equipment | $2,935 | $3,500 | - | - | - | - | $2,935 | |
| TOTAL RECOMMENDED | $96,166 | $82,805 |
$12,720
128,934
kWh
|
$4,792
-
kW-mo/yr
|
$5,553
-
lb
|
$70,166 | $2,935 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs