| Assessment Year | 2004 |
|---|---|
| Principal Product | molded rubber |
| NAICS | 326299: All Other Rubber Product Manufacturing |
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
80,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $582,671 | 5,414,543 |
kWh
|
$0.11 |
| Electricity Demand | $167,205 | 13,124 |
kW-mo/yr
|
$12.74 |
| Natural Gas | $7,132 | 500 |
MMBtu
|
$14.26 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $110,465 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $78,851 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $14,979 | $15,000 |
$15,817
147,000
kWh
|
$3,746
-
kW-mo/yr
|
$(-4,584.0)
-
MMBtu
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $14,470 | $600 |
$14,470
134,458
kWh
|
- | - | - | - | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $7,390 | - |
$7,390
68,720
kWh
|
- | - | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,253 | $192 |
$3,438
31,950
kWh
|
$815
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,128 | - |
$2,542
23,621
kWh
|
$586
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,645 | $3,125 |
$2,645
24,585
kWh
|
- | - | - | - | |
| 07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $6,600 | $15,000 | - | - | - |
$6,600
-
lb
|
- | |
| 08 | 3.2176: Increase use of automation | $57,000 | $110,000 | - | - | - | - | $57,000 | |
| TOTAL RECOMMENDED | $110,465 | $143,917 |
$46,302
430,334
kWh
|
$5,147
-
kW-mo/yr
|
$(-4,584.0)
-
MMBtu
|
$6,600
-
lb
|
$57,000 | ||
| TOTAL IMPLEMENTED | $78,851 | $110,792 |
$20,450
190,029
kWh
|
$1,401
-
kW-mo/yr
|
- | - | $57,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs