| Assessment Year | 2004 |
|---|---|
| Principal Product | Paper |
| NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
| SIC | 2672: Coated and Laminated Paper, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
70,000
ft2
|
| Annual Production | 60,000,000
lb
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $83,403 | 666,840 |
kWh
|
$0.13 |
| Electricity Demand | $11,616 | 1,416 |
kW-mo/yr
|
$8.20 |
| LPG | $4,681 | 500 |
MMBtu
|
$9.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $115,625 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $110,420 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7134: Use photocell controls | $4,358 | $410 |
$4,358
34,836
kWh
|
- | - | - | |
| 02 | 2.6218: Turn off equipment when not in use | $643 | $453 |
$643
2,200
kWh
|
- | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $204 | - |
$163
1,306
kWh
|
$41
-
kW-mo/yr
|
- | - | |
| 04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $2,220 | $5,000 | - | - |
$2,220
-
lb
|
- | |
| 05 | 4.441: Install automatic packing equipment | $108,200 | $110,000 | - | - | - | $108,200 | |
| TOTAL RECOMMENDED | $115,625 | $115,863 |
$5,164
38,342
kWh
|
$41
-
kW-mo/yr
|
$2,220
-
lb
|
$108,200 | ||
| TOTAL IMPLEMENTED | $110,420 | $115,000 | - | - |
$2,220
-
lb
|
$108,200 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs