Assessment Year | 2003 |
---|---|
Principal Product | Frozen Fruits/Vegetables |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
44,500
ft2
|
Annual Production | 42,500,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $291,142 | 2,535,524 |
kWh
|
$0.11 |
Electricity Demand | $85,431 | 7,587 |
kW-mo/yr
|
$11.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $70,583 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,913 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,055 | $3,750 |
$2,780
24,622
kWh
|
$275
-
kW-mo/yr
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,922 | - |
$2,362
20,924
kWh
|
$560
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,991 | $300 |
$1,656
14,682
kWh
|
$335
-
kW-mo/yr
|
- | - | - | |
04 | 2.7145: Install skylights | $872 | $1,000 |
$521
4,612
kWh
|
$351
-
kW-mo/yr
|
- | - | - | |
05 | 3.3128: Utilize other methods to remove contaminants | $47,600 | $40,000 | - | - | - | - | $47,600 | |
06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $11,188 | $10,000 | - | - | - |
$11,188
-
lb
|
- | |
07 | 3.4111: Use closed cycle process to minimize waste water production | $2,955 | $9,800 | - | - |
$2,955
-
Tgal
|
- | - | |
TOTAL RECOMMENDED | $70,583 | $64,850 |
$7,319
64,840
kWh
|
$1,521
-
kW-mo/yr
|
$2,955
-
Tgal
|
$11,188
-
lb
|
$47,600 | ||
TOTAL IMPLEMENTED | $4,913 | $300 |
$4,018
35,606
kWh
|
$895
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs