Assessment Year | 2003 |
---|---|
Principal Product | Portable Process Instrumentation |
NAICS | 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3825: Instruments for Measuring and Testing of Electricity and Electrical Signals |
Sales Range | $10 M to 50M |
# of Employees | 78 |
Plant Area |
61,000
ft2
|
Annual Production | 60,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,391 | 644,486 |
kWh
|
$0.13 |
Electricity Demand | $21,028 | 2,461 |
kW-mo/yr
|
$8.54 |
Natural Gas | $150 | 20 |
MMBtu
|
$7.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,437 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,187 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $10,146 | $19,000 |
$10,146
77,511
kWh
|
- | - | |
02 | 2.7134: Use photocell controls | $3,064 | $2,000 |
$2,014
15,390
kWh
|
$1,050
-
kW-mo/yr
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $501 | - |
$371
2,837
kWh
|
$130
-
kW-mo/yr
|
- | |
04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $2,622 | $5,000 | - | - | $2,622 | |
05 | 4.522: Modify storage space to avoid rental of a warehouse | $31,104 | - | - | - | $31,104 | |
TOTAL RECOMMENDED | $47,437 | $26,000 |
$12,531
95,738
kWh
|
$1,180
-
kW-mo/yr
|
$33,726 | ||
TOTAL IMPLEMENTED | $6,187 | $7,000 |
$2,385
18,227
kWh
|
$1,180
-
kW-mo/yr
|
$2,622 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs