ITAC Assessment: SD0304
ITAC logo
ITAC Assessment: SD0304
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product Plastic PET bottles
NAICS
n/a
SIC 3085: Plastics Bottles
Sales Range n/a
# of Employees 160
Plant Area 500,000
ft2
Annual Production 28,000,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $4,891,101 56,303,903
kWh
Electricity Demand $713,832 86,284
kW-mo/yr
Electricity Fees $5,641 -
Natural Gas $136,781 26,956
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $762,789 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $258,459 $242,000 $222,510
3,006,892
kWh
$35,949
-
kW-mo/yr
- -
02 2.1311: Replace electrically-operated equipment with fossil fuel equipment $362,272 $628,750 $312,904
4,228,438
kWh
$49,368
-
kW-mo/yr
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $43,804 $29,000 $37,776
510,496
kWh
$6,028
-
kW-mo/yr
- -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $32,788 $39,000 $28,430
384,198
kWh
$4,358
-
kW-mo/yr
- -
05 2.7134: Use photocell controls $21,520 $3,000 $13,333
180,180
kWh
$8,187
-
kW-mo/yr
- -
06 2.7111: Reduce illumination to minimum necessary levels $13,050 - $11,313
152,880
kWh
$1,737
-
kW-mo/yr
- -
07 2.2511: Insulate bare equipment $12,405 $2,120 $12,405
167,167
kWh
- - -
08 2.7135: Install occupancy sensors $2,591 $600 - $2,591
-
kW-mo/yr
- -
09 3.6193: Install equipment (eg compactor) to reduce disposal costs $10,400 $15,000 - - - $10,400
-
lb
10 3.6193: Install equipment (eg compactor) to reduce disposal costs $5,500 $2,500 - - $5,500
-
gal
-
TOTAL RECOMMENDED $762,789 $961,970 $638,671
8,630,251
kWh
$108,218
-
kW-mo/yr
$5,500
-
gal
$10,400
-
lb
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs