| Assessment Year | 2002 |
|---|---|
| Principal Product | Aerospace teflon parts |
| NAICS |
n/a
|
| SIC | 3061: Molded, Extruded, and Lathe-Cut Mechanical Rubber Goods |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
32,000
ft2
|
| Annual Production | 1,500,000
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $225,221 | 1,839,865 |
kWh
|
$0.12 |
| Electricity Demand | $37,882 | 4,518 |
kW-mo/yr
|
$8.38 |
| Electricity Fees | $1,811 | - |
|
- |
| Natural Gas | $7,096 | 1,364 |
MMBtu
|
$5.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $100,471 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $30,135 | $58,000 |
$22,785
186,150
kWh
|
$7,350
-
kW-mo/yr
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,968 | $320 |
$5,836
47,683
kWh
|
$1,132
-
kW-mo/yr
|
- | - | |
| 03 | 2.7212: Install or upgrade insulation on hvac distribution systems | $3,733 | $1,000 |
$3,733
30,496
kWh
|
- | - | - | |
| 04 | 2.7135: Install occupancy sensors | $2,775 | $6,000 |
$1,792
14,640
kWh
|
$983
-
kW-mo/yr
|
- | - | |
| 05 | 2.2511: Insulate bare equipment | $2,690 | $1,200 |
$2,690
21,980
kWh
|
- | - | - | |
| 06 | 3.1191: Change procedures / equipment / operating conditions | $1,586 | $1,000 |
$1,326
10,841
kWh
|
$260
-
kW-mo/yr
|
- | - | |
| 07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $1,584 | $2,000 | - | - |
$1,584
-
lb
|
- | |
| 08 | 3.2176: Increase use of automation | $51,000 | $50,000 | - | - | - | $51,000 | |
| TOTAL RECOMMENDED | $100,471 | $119,520 |
$38,162
311,790
kWh
|
$9,725
-
kW-mo/yr
|
$1,584
-
lb
|
$51,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs