Assessment Year | 2002 |
---|---|
Principal Product | Paper bags |
NAICS |
n/a
|
SIC | 2674: Uncoated Paper and Multiwall Bags |
Sales Range | n/a |
# of Employees | 95 |
Plant Area |
100,000
ft2
|
Annual Production | 33,175
ton
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $304,198 | 2,675,804 |
kWh
|
$0.11 |
Electricity Demand | $46,792 | 5,663 |
kW-mo/yr
|
$8.26 |
Electricity Fees | $720 | - |
|
- |
Natural Gas | $7,854 | 1,027 |
MMBtu
|
$7.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,740 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,836 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,966 | $720 |
$8,812
77,505
kWh
|
$1,154
-
kW-mo/yr
|
- | - | - | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $5,989 | $1,000 |
$5,287
46,500
kWh
|
$702
-
kW-mo/yr
|
- | - | - | |
03 | 2.7226: Use computer programs to optimize hvac performance | $4,898 | $1,000 |
$4,898
43,076
kWh
|
- | - | - | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,115 | $6,000 |
$2,752
24,205
kWh
|
$363
-
kW-mo/yr
|
- | - | - | |
05 | 2.1221: Replace obsolete burners with more efficient ones | $2,448 | $2,560 | - | - |
$2,448
-
MMBtu
|
- | - | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $2,446 | - |
$2,161
19,008
kWh
|
$285
-
kW-mo/yr
|
- | - | - | |
07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $8,422 | $10,000 | - | - | - |
$8,422
-
lb
|
- | |
08 | 2.8123: Pay utility bills on time | $7,456 | - | - | - | - | - | $7,456 | |
TOTAL RECOMMENDED | $44,740 | $21,280 |
$23,910
210,294
kWh
|
$2,504
-
kW-mo/yr
|
$2,448
-
MMBtu
|
$8,422
-
lb
|
$7,456 | ||
TOTAL IMPLEMENTED | $20,836 | $13,280 |
$8,812
77,505
kWh
|
$1,154
-
kW-mo/yr
|
$2,448
-
MMBtu
|
$8,422
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs