Assessment Year | 2002 |
---|---|
Principal Product | beer |
NAICS |
n/a
|
SIC | 2085: Distilled and Blended Liquors |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
20,000
ft2
|
Annual Production | 20,000
bbl
|
Production Hrs. Annual | 3,500
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $44,167 | 310,080 |
kWh
|
$0.14 |
Electricity Demand | $12,301 | 1,085 |
kW-mo/yr
|
$11.34 |
Electricity Fees | $537 | - |
|
- |
Natural Gas | $42,120 | 3,519 |
MMBtu
|
$11.97 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,009 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,904 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.2441: Preheat boiler makeup water with waste process heat | $9,512 | $6,000 | - |
$9,512
-
MMBtu
|
- | |
02 | 2.2522: Isolate hot or cold equipment | $3,123 | $5,200 |
$3,123
21,945
kWh
|
- | - | |
03 | 2.1221: Replace obsolete burners with more efficient ones | $4,969 | $2,000 | - |
$4,969
-
MMBtu
|
- | |
04 | 2.2694: Use highest temperature for chilling or cold storage | $501 | $20 |
$501
12
kWh
|
- | - | |
05 | 3.4116: Meter recycled water (to reduce sewer charges) | $10,904 | $2,000 | - | - |
$10,904
-
Tgal
|
|
TOTAL RECOMMENDED | $29,009 | $15,220 |
$3,624
21,957
kWh
|
$14,481
-
MMBtu
|
$10,904
-
Tgal
|
||
TOTAL IMPLEMENTED | $10,904 | $2,000 | - | - |
$10,904
-
Tgal
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs