| Assessment Year | 2002 | 
|---|---|
| Principal Product | laminated panels for motor homes/RV's electronic and furniture industrie | 
| NAICS | 
                             n/a 
                     | 
    
| SIC | 3448: Prefabricated Metal Buildings and Components | 
| Sales Range | $10 M  to 50M  | 
    
| # of Employees | 120 | 
| Plant Area | 
                            120,000
                 
ft2
 
                     | 
    
| Annual Production | 20,000,000
             
thousand feet
 
         | 
    
| Production Hrs. Annual | 4,250
             
hrs
 
         | 
    
| Location (State) | California | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $196,204 | 1,770,957 | 
             
kWh
 
         | 
        $0.11 | 
| Electricity Demand | $72,863 | 8,757 | 
             
kW-mo/yr
 
         | 
        $8.32 | 
| Electricity Fees | $1,440 | - | 
             | 
        - | 
| Natural Gas | $1,534 | 118 | 
             
MMBtu
 
         | 
        $13.00 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $182,753 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $57,485 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | 
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $42,804 | $52,000 | 
                        $35,316
                                                     318,736
                                 
                                            
kWh
 
                             | 
                                                                                
                        $7,488
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $4,322 | $3,700 | 
                        $3,565
                                                     32,171
                                 
                                            
kWh
 
                             | 
                                                                                
                        $757
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | |
| 03 | 2.7135: Install occupancy sensors | $5,121 | $1,000 | 
                        $3,199
                                                     28,875
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,922
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,238 | $280 | 
                        $4,299
                                                     38,804
                                 
                                            
kWh
 
                             | 
                                                                                
                        $939
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | |
| 05 | 2.7144: Install spectral reflectors / delamp | $2,851 | $4,092 | 
                        $2,124
                                                     19,172
                                 
                                            
kWh
 
                             | 
                                                                                
                        $727
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | |
| 06 | 3.2176: Increase use of automation | $122,000 | $45,000 | - | - | $122,000 | |
| 07 | 2.8123: Pay utility bills on time | $417 | - | - | - | $417 | |
| TOTAL RECOMMENDED | $182,753 | $106,072 | 
                        $48,503
                                                     437,758
                                 
                                            
kWh
 
                             | 
                                                                                
                        $11,833
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                $122,417 | ||
| TOTAL IMPLEMENTED | $57,485 | $56,980 | 
                        $46,379
                                                     418,586
                                 
                                            
kWh
 
                             | 
                                                                                
                        $11,106
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs