Assessment Year 2002
Principal Product Pneumatic,hydraulic and fuel fittings
NAICS
n/a
SIC 3494: Valves and Pipe Fittings, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 400
Plant Area 609,840
ft2
Annual Production 0
units
Production Hrs. Annual 6,732
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $890,354 6,531,261
kWh
Electricity Demand $55,946 7,146
kW-mo/yr
Electricity Fees $5,546 -
Natural Gas $39,991 5,076
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $283,081 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $41,211

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Other Liquid (haz) Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,881 $1,440 $5,221
62,981
kWh
$1,660
-
kW-mo/yr
- - - -
02 2.1311: Replace electrically-operated equipment with fossil fuel equipment $51,269 $35,000 $33,485
403,920
kWh
$17,784
-
kW-mo/yr
- - - -
03 2.4239: Eliminate or reduce compressed air usage $27,450 $20,000 $20,817
251,104
kWh
$6,633
-
kW-mo/yr
- - - -
04 2.3137: Use power during off-peak periods $30,695 - - $19,184
-
kW-mo/yr
$11,511 - - -
05 2.7145: Install skylights $41,280 $31,500 - $23,134
-
kW-mo/yr
$18,146 - - -
06 2.4322: Use or replace with energy efficient substitutes $13,283 $3,000 $10,073
170,214
kWh
$3,210
-
kW-mo/yr
- - - -
07 2.7135: Install occupancy sensors $3,635 $2,800 $3,635
43,842
kWh
- - - - -
08 2.6218: Turn off equipment when not in use $20,169 $2,500 $15,249
186,112
kWh
$4,920
-
kW-mo/yr
- - - -
09 3.3131: Use evaporation to concentrate material $6,810 $3,000 - - - $6,810
-
gal
- -
10 3.3131: Use evaporation to concentrate material $825 $1,500 - - - - $825
-
lb
-
11 4.445: Install equipment to move product $80,784 $100,000 - - - - - $80,784
TOTAL RECOMMENDED $283,081 $200,740 $88,480
1,118,173
kWh
$76,525
-
kW-mo/yr
$29,657 $6,810
-
gal
$825
-
lb
$80,784
TOTAL IMPLEMENTED $41,211 $4,240 $8,856
106,823
kWh
$20,844
-
kW-mo/yr
$11,511 - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Other Liquid (haz) Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs