Assessment Year | 2001 |
---|---|
Principal Product | Brass mill rod and shape products |
NAICS |
n/a
|
SIC | 3351: Rolling, Drawing, and Extruding Of Copper |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
320,000
ft2
|
Annual Production | 40,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $720,008 | 15,981,904 |
kWh
|
$0.045 |
Electricity Demand | $31,122 | 41,786 |
kW-mo/yr
|
$0.74 |
Electricity Fees | $28,175 | - |
|
- |
Natural Gas | $169,721 | 33,995 |
MMBtu
|
$4.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $591,362 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,478 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $34,478 | $1,400 |
$33,380
741,762
kWh
|
$1,098
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.4321: Upgrade obsolete equipment | $32,897 | $60,000 |
$32,002
709,578
kWh
|
$895
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.7145: Install skylights | $17,602 | $37,000 |
$15,560
345,000
kWh
|
$2,042
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.4322: Use or replace with energy efficient substitutes | $1,025 | $2,250 |
$972
21,560
kWh
|
$53
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $21,557 | $45,000 |
$32,472
720,000
kWh
|
$1,776
-
kW-mo/yr
|
$(-12,691.0)
-
MMBtu
|
- | - | - | - | |
06 | 2.4321: Upgrade obsolete equipment | $465,613 | $1,000,000 |
$39,293
871,250
kWh
|
$1,820
-
kW-mo/yr
|
- |
$48,000
-
gal
|
- | $376,500 | - | |
07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $4,190 | $15,000 | - | - | - | - | - | - | $4,190 | |
08 | 3.7198: Reduce / eliminate use of disposable product | $14,000 | $5,800 | - | - | - | - |
$14,000
-
lb
|
- | - | |
TOTAL RECOMMENDED | $591,362 | $1,166,450 |
$153,679
3,409,150
kWh
|
$7,684
-
kW-mo/yr
|
$(-12,691.0)
-
MMBtu
|
$48,000
-
gal
|
$14,000
-
lb
|
$376,500 | $4,190 | ||
TOTAL IMPLEMENTED | $34,478 | $1,400 |
$33,380
741,762
kWh
|
$1,098
-
kW-mo/yr
|
- | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs