Assessment Year 2000
Principal Product metal plating
NAICS
n/a
SIC 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 30
Plant Area 11,100
ft2
Annual Production 50,000
pieces
Production Hrs. Annual 2,125
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $34,442 617,819
kWh
Electricity Demand $38,197 6,762
kW-mo/yr
Electricity Fees $600 -
Natural Gas $8,192 1,414
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $42,702 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,302

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $15,319 $14,000 $13,199
236,518
kWh
$7,973
-
kW-mo/yr
$(-5,853.0)
-
MMBtu
-
02 2.2511: Insulate bare equipment $7,454 $5,833 $3,832
68,581
kWh
$2,352
-
kW-mo/yr
$1,270
-
MMBtu
-
03 2.1311: Replace electrically-operated equipment with fossil fuel equipment $6,787 $2,500 $1,883
33,705
kWh
$5,858
-
kW-mo/yr
$(-954.0)
-
MMBtu
-
04 2.1311: Replace electrically-operated equipment with fossil fuel equipment $3,523 $4,000 $1,205
21,688
kWh
$2,929
-
kW-mo/yr
$(-611.0)
-
MMBtu
-
05 2.4239: Eliminate or reduce compressed air usage $2,081 $3,000 $2,081
37,222
kWh
- - -
06 2.1311: Replace electrically-operated equipment with fossil fuel equipment $905 $900 $397
7,034
kWh
$610
-
kW-mo/yr
$(-102.0)
-
MMBtu
-
07 2.4231: Reduce the pressure of compressed air to the minimum required $515 - $235
4,103
kWh
$280
-
kW-mo/yr
- -
08 4.651: Install back-up equipment $6,118 $7,000 - - - $6,118
TOTAL RECOMMENDED $42,702 $37,233 $22,832
408,851
kWh
$20,002
-
kW-mo/yr
$(-6,250.0)
-
MMBtu
$6,118
TOTAL IMPLEMENTED $7,302 $2,500 $2,118
37,808
kWh
$6,138
-
kW-mo/yr
$(-954.0)
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs