Assessment Year | 1999 |
---|---|
Principal Product | Analytical Intruments |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
60,000
ft2
|
Annual Production | 200
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $54,038 | 757,327 |
kWh
|
$0.071 |
Electricity Demand | $17,554 | 2,119 |
kW-mo/yr
|
$8.28 |
Natural Gas | $2,690 | 451 |
MMBtu
|
$5.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,502 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,465 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,324 | $15,387 |
$2,990
41,911
kWh
|
$1,334
-
kW-mo/yr
|
- | - | |
02 | 2.7144: Install spectral reflectors / delamp | $6,037 | $10,200 |
$4,175
58,617
kWh
|
$1,862
-
kW-mo/yr
|
- | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,775 | $1,374 |
$759
10,551
kWh
|
$1,016
-
kW-mo/yr
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $376 | - |
$146
2,052
kWh
|
$230
-
kW-mo/yr
|
- | - | |
05 | 3.5217: Reuse / recycle/ sell paper products | $3,990 | - | - | - |
$3,990
-
lb
|
- | |
06 | 4.522: Modify storage space to avoid rental of a warehouse | $18,000 | $6,304 | - | - | - | $18,000 | |
TOTAL RECOMMENDED | $34,502 | $33,265 |
$8,070
113,131
kWh
|
$4,442
-
kW-mo/yr
|
$3,990
-
lb
|
$18,000 | ||
TOTAL IMPLEMENTED | $10,465 | $16,761 |
$3,895
54,514
kWh
|
$2,580
-
kW-mo/yr
|
$3,990
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs