Assessment Year | 1999 |
---|---|
Principal Product | Steel frames for CRT |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 124 |
Plant Area |
217,000
ft2
|
Annual Production | 2,200,000
pieces
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $208,876 | 4,822,978 |
kWh
|
$0.043 |
Electricity Demand | $150,572 | 8,849 |
kW-mo/yr
|
$17.02 |
Natural Gas | $55,131 | 10,676 |
MMBtu
|
$5.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $256,636 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,815 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $2,815 | $240 |
$1,590
36,635
kWh
|
$1,225
-
kW-mo/yr
|
- | - | - | |
02 | 2.2424: Use heat in flue gases to preheat products or materials | $62,663 | $2,000 | - | - |
$62,663
-
MMBtu
|
- | - | |
03 | 2.2422: Use waste heat from hot flue gases to generate steam | $39,599 | $12,550 |
$18,867
435,815
kWh
|
$20,732
-
kW-mo/yr
|
- | - | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $40,547 | $65,000 |
$19,319
446,073
kWh
|
$21,228
-
kW-mo/yr
|
- | - | - | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $49,560 | $10,000 |
$34,294
792,204
kWh
|
$32,659
-
kW-mo/yr
|
$(-17,393.0)
-
MMBtu
|
- | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $32,441 | $102,000 |
$20,466
472,743
kWh
|
$11,975
-
kW-mo/yr
|
- | - | - | |
07 | 2.2414: Use waste heat from hot flue gases to preheat | $25,085 | $18,000 |
$3,429
79,132
kWh
|
$3,266
-
kW-mo/yr
|
$18,390
-
MMBtu
|
- | - | |
08 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $1,000 | - | - | - | - | - |
$1,000
-
lb
|
|
09 | 3.8211: Convert to aqueous cleaning system | $2,926 | $1,000 | - | - | - |
$2,926
-
gal
|
- | |
TOTAL RECOMMENDED | $256,636 | $210,790 |
$97,965
2,262,602
kWh
|
$91,085
-
kW-mo/yr
|
$63,660
-
MMBtu
|
$2,926
-
gal
|
$1,000
-
lb
|
||
TOTAL IMPLEMENTED | $3,815 | $240 |
$1,590
36,635
kWh
|
$1,225
-
kW-mo/yr
|
- | - |
$1,000
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs