| Assessment Year | 1999 |
|---|---|
| Principal Product | nylon film |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
120,000
ft2
|
| Annual Production | 2,400,000
lb
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $178,557 | 2,657,972 |
kWh
|
$0.067 |
| Electricity Demand | $52,024 | 6,368 |
kW-mo/yr
|
$8.17 |
| Natural Gas | $6,404 | 1,031 |
MMBtu
|
$6.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $219,222 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $145,735 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $785 | - |
$658
9,672
kWh
|
$127
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $10,261 | - |
$7,651
114,009
kWh
|
$2,610
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7144: Install spectral reflectors / delamp | $3,358 | $6,750 |
$2,545
37,808
kWh
|
$813
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $21,102 | $2,000 |
$17,548
261,137
kWh
|
$3,554
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $36,281 | $5,000 |
$44,876
667,937
kWh
|
$9,093
-
kW-mo/yr
|
$(-17,688.0)
-
MMBtu
|
- | - | |
| 06 | 2.2511: Insulate bare equipment | $1,700 | $370 |
$1,438
21,395
kWh
|
$262
-
kW-mo/yr
|
- | - | - | |
| 07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $25,400 | $10,000 | - | - | - |
$25,400
-
lb
|
- | |
| 08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $22,360 | $3,000 | - | - | - |
$22,360
-
lb
|
- | |
| 09 | 3.1192: Reduce scrap production | $97,975 | - | - | - | - | - | $97,975 | |
| TOTAL RECOMMENDED | $219,222 | $27,120 |
$74,716
1,111,958
kWh
|
$16,459
-
kW-mo/yr
|
$(-17,688.0)
-
MMBtu
|
$47,760
-
lb
|
$97,975 | ||
| TOTAL IMPLEMENTED | $145,735 | $13,000 | - | - | - |
$47,760
-
lb
|
$97,975 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs