Assessment Year 1999
Principal Product nylon film
NAICS
n/a
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $10
M
to 50
M
# of Employees 85
Plant Area 120,000
ft2
Annual Production 2,400,000
lb
Production Hrs. Annual 7,200
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $178,557 2,657,972
kWh
Electricity Demand $52,024 6,368
kW-mo/yr
Natural Gas $6,404 1,031
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $219,222 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $145,735

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Primary Product Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $785 - $658
9,672
kWh
$127
-
kW-mo/yr
- - -
02 2.7111: Reduce illumination to minimum necessary levels $10,261 - $7,651
114,009
kWh
$2,610
-
kW-mo/yr
- - -
03 2.7144: Install spectral reflectors / delamp $3,358 $6,750 $2,545
37,808
kWh
$813
-
kW-mo/yr
- - -
04 2.2437: Recover waste heat from equipment $21,102 $2,000 $17,548
261,137
kWh
$3,554
-
kW-mo/yr
- - -
05 2.1311: Replace electrically-operated equipment with fossil fuel equipment $36,281 $5,000 $44,876
667,937
kWh
$9,093
-
kW-mo/yr
$(-17,688.0)
-
MMBtu
- -
06 2.2511: Insulate bare equipment $1,700 $370 $1,438
21,395
kWh
$262
-
kW-mo/yr
- - -
07 3.6193: Install equipment (eg compactor) to reduce disposal costs $25,400 $10,000 - - - $25,400
-
lb
-
08 3.5315: Lease / purchase baler; sell cardboard to recycler $22,360 $3,000 - - - $22,360
-
lb
-
09 3.1192: Reduce scrap production $97,975 - - - - - $97,975
TOTAL RECOMMENDED $219,222 $27,120 $74,716
1,111,958
kWh
$16,459
-
kW-mo/yr
$(-17,688.0)
-
MMBtu
$47,760
-
lb
$97,975
TOTAL IMPLEMENTED $145,735 $13,000 - - - $47,760
-
lb
$97,975
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs