Assessment Year 1997
Principal Product Cabinets for TV's and computer monitors
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 50,000
ft2
Annual Production 7,100,000
pieces
Production Hrs. Annual 8,400
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $517,230 9,464,830
kWh
Electricity Demand $208,579 16,449
kW-mo/yr
Natural Gas $392 26
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $390,921 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $129,858

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.4133: Use most efficient type of electric motors $7,361 $6,880 $4,989
90,856
kWh
$2,372
-
kW-mo/yr
- - -
02 2.4133: Use most efficient type of electric motors $6,487 $7,800 $3,964
72,098
kWh
$2,523
-
kW-mo/yr
- - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $3,849 $100 $3,849
70,047
kWh
- - - -
04 2.2515: Use optimum thickness insulation $2,400 $2,250 $1,830
33,118
kWh
$570
-
kW-mo/yr
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $3,073 $4,231 $2,410
32,532
kWh
$663
-
kW-mo/yr
- - -
06 2.7144: Install spectral reflectors / delamp $1,663 $955 $1,253
16,999
kWh
$410
-
kW-mo/yr
- - -
07 3.6193: Install equipment (eg compactor) to reduce disposal costs $11,800 $6,000 - - $11,800
-
gal
- -
08 3.8224: Convert to less toxic hydrocarbon cleaners $12,985 - - - - - $12,985
09 3.6193: Install equipment (eg compactor) to reduce disposal costs $3,620 $9,000 - - - $3,620 -
10 3.7211: Modify material application methods $1,620 $2,600 - - - - $1,620
11 4.221: Use only amount of packaging material necessary $261,063 $9,000 - - - $261,063 -
12 4.441: Install automatic packing equipment $75,000 $20,000 - - - $75,000 -
TOTAL RECOMMENDED $390,921 $68,816 $18,295
315,650
kWh
$6,538
-
kW-mo/yr
$11,800
-
gal
$339,683 $14,605
TOTAL IMPLEMENTED $129,858 $59,816 $18,295
315,650
kWh
$6,538
-
kW-mo/yr
$11,800
-
gal
$78,620 $14,605
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs