Assessment Year 1996
Principal Product Protective packaging for electronic components
NAICS
n/a
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area 120,000
ft2
Annual Production 2,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $244,797 4,094,666
kWh
Electricity Demand $62,228 9,463
kW-mo/yr
Natural Gas $12,533 1,904
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $139,941 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $56,936

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Solid Waste (non-haz) Savings
01 2.4133: Use most efficient type of electric motors $8,311 $13,640 $8,311
116,940
kWh
-
02 2.6231: Utilize controls to operate equipment only when needed $7,214 $1,500 $7,214
124,560
kWh
-
03 2.6232: Install set-back timers $1,459 $600 $1,459
25,205
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $42,795 $26,067 $42,795
572,392
kWh
-
05 2.7144: Install spectral reflectors / delamp $32,996 $11,835 $32,996
446,366
kWh
-
06 2.7135: Install occupancy sensors $9,126 $1,230 $9,126
120,164
kWh
-
07 3.5315: Lease / purchase baler; sell cardboard to recycler $38,040 $1,000 - $38,040
-
lb
TOTAL RECOMMENDED $139,941 $55,872 $101,901
1,405,627
kWh
$38,040
-
lb
TOTAL IMPLEMENTED $56,936 $16,470 $18,896
262,309
kWh
$38,040
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs