| Assessment Year | 1996 |
|---|---|
| Principal Product | Scanners and computer peripherals |
| NAICS |
n/a
|
| SIC | 3577: Computer Peripheral Equipment, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 221 |
| Plant Area |
105,000
ft2
|
| Annual Production | 4,500
units
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $204,046 | 1,762,016 |
kWh
|
$0.12 |
| Electricity Demand | $35,939 | 4,938 |
kW-mo/yr
|
$7.28 |
| Natural Gas | $5,715 | 871 |
MMBtu
|
$6.56 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,254 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,844 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (haz) Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,616 | $2,210 |
$1,616
14,068
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,410 | $40 |
$1,410
18,171
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $371 | $756 |
$371
3,224
kWh
|
- | |
| 04 | 2.7144: Install spectral reflectors / delamp | $3,949 | $6,275 |
$3,949
35,463
kWh
|
- | |
| 05 | 3.8143: Recycle cleaning solvent and reuse | $7,908 | $7,200 | - |
$7,908
-
gal
|
|
| TOTAL RECOMMENDED | $15,254 | $16,481 |
$7,346
70,926
kWh
|
$7,908
-
gal
|
||
| TOTAL IMPLEMENTED | $13,844 | $16,441 |
$5,936
52,755
kWh
|
$7,908
-
gal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs