ITAC Assessment: SD0134
ITAC logo
ITAC Assessment: SD0134
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Photovoltaic Cells, Modules & Systems
NAICS
n/a
SIC 3674: Semiconductors and Related Devices
Sales Range $5
M
to 10
M
# of Employees 103
Plant Area 22,000
ft2
Annual Production 1,000,000
lb
Production Hrs. Annual 15,400
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $207,101 3,483,587
kWh
Electricity Demand $46,278 16,154
kW-mo/yr
Natural Gas $516 37
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,942 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Other Liquid (haz) Savings Solid Waste (haz) Savings
01 2.4133: Use most efficient type of electric motors $2,991 $3,350 $2,991
37,515
kWh
- -
02 2.7313: Recycle air for heating, ventilation and air conditioning $2,747 $2,500 $2,747
31,946
kWh
- -
03 2.2514: Cover open tanks $679 $161 $679
6,448
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,979 $1,860 $1,979
19,930
kWh
- -
05 2.7144: Install spectral reflectors / delamp $3,101 $5,520 $3,101
31,360
kWh
- -
06 3.4114: Replace city water with recycled water via cooling tower $1,336 $1,100 - $1,336
-
gal
-
07 3.5314: Use in-process recycling whenever possible $878 $100 - - $878
-
lb
08 3.6193: Install equipment (eg compactor) to reduce disposal costs $231 $500 - - $231
-
lb
TOTAL RECOMMENDED $13,942 $15,091 $11,497
127,199
kWh
$1,336
-
gal
$1,109
-
lb
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Other Liquid (haz) Savings Solid Waste (haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs