Assessment Year | 1995 |
---|---|
Principal Product | Printed Circuit Boards |
NAICS |
n/a
|
SIC | 3672: Printed Circuit Boards |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
35,000
ft2
|
Annual Production | 35,000
units
|
Production Hrs. Annual | 11,440
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $267,247 | 2,273,154 |
kWh
|
$0.12 |
Natural Gas | $4,203 | 456 |
MMBtu
|
$9.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,710 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,939 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $6,089 | $5,020 |
$6,089
57,151
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,109 | $15 |
$2,109
19,930
kWh
|
|
03 | 2.2437: Recover waste heat from equipment | $662 | $300 |
$662
6,155
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,277 | $20,545 |
$15,277
141,559
kWh
|
|
05 | 2.7144: Install spectral reflectors / delamp | $20,454 | $12,500 |
$20,454
190,211
kWh
|
|
06 | 2.7135: Install occupancy sensors | $1,119 | $484 |
$1,119
10,258
kWh
|
|
TOTAL RECOMMENDED | $45,710 | $38,864 |
$45,710
425,264
kWh
|
||
TOTAL IMPLEMENTED | $42,939 | $38,549 |
$42,939
399,179
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs