| Assessment Year | 1995 | 
|---|---|
| Principal Product | Printed Circuit Boards | 
| NAICS | 
                             n/a 
                     | 
    
| SIC | 3672: Printed Circuit Boards | 
| Sales Range | $5 M  to 10M  | 
    
| # of Employees | 80 | 
| Plant Area | 
                            60,000
                 
ft2
 
                     | 
    
| Annual Production | 1,000,000
             
thousand feet
 
         | 
    
| Production Hrs. Annual | 6,552
             
hrs
 
         | 
    
| Location (State) | California | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $174,346 | 1,856,682 | 
             
kWh
 
         | 
        $0.094 | 
| Natural Gas | $29,607 | 4,506 | 
             
MMBtu
 
         | 
        $6.57 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $47,566 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $24,283 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | 
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $5,107 | $4,150 | 
                        $5,107
                                                     54,513
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 02 | 2.2511: Insulate bare equipment | $4,410 | $4,925 | - | 
                        $4,410
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | - | |
| 03 | 2.2136: Install / repair insulation on steam lines | $2,610 | $493 | - | 
                        $2,610
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | - | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $1,483 | $2,500 | 
                        $1,483
                                                     15,826
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 05 | 2.2514: Cover open tanks | $593 | $227 | - | 
                        $593
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,196 | $8,381 | 
                        $5,196
                                                     55,393
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 07 | 2.7144: Install spectral reflectors / delamp | $7,758 | $6,675 | 
                        $7,758
                                                     76,202
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 08 | 2.7135: Install occupancy sensors | $995 | $648 | 
                        $995
                                                     9,672
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 09 | 2.7134: Use photocell controls | $526 | $300 | 
                        $526
                                                     5,569
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | |
| 10 | 3.6114: Use precipitating agents in waste water treatment that produce the least quantity of waste | $17,352 | $7,000 | - | - | 
                        $17,352
                                                     -
                                 
                                            
gal
 
                             | 
                                                                                - | |
| 11 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $936 | - | - | - | - | 
                        $936
                                                     -
                                 
                                            
lb
 
                             | 
                                    |
| 12 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $600 | - | - | - | - | 
                        $600
                                                     -
                                 
                                            
lb
 
                             | 
                                    |
| TOTAL RECOMMENDED | $47,566 | $35,299 | 
                        $21,065
                                                     217,175
                                 
                                            
kWh
 
                             | 
                                                                                
                        $7,613
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                
                        $17,352
                                                     -
                                 
                                            
gal
 
                             | 
                                                                                
                        $1,536
                                                     -
                                 
                                            
lb
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $24,283 | $22,426 | 
                        $19,544
                                                     201,934
                                 
                                            
kWh
 
                             | 
                                                                                
                        $3,203
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | 
                        $1,536
                                                     -
                                 
                                            
lb
 
                             | 
                                    ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | |||