| Assessment Year | 1995 |
|---|---|
| Principal Product | High Power Supply Switches |
| NAICS |
n/a
|
| SIC | 3679: Electronic Components, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 165 |
| Plant Area |
43,000
ft2
|
| Annual Production | 18,000
pieces
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $124,463 | 1,172,626 |
kWh
|
$0.11 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,865 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,147 | - |
$6,147
-
kWh
|
|
| 02 | 2.2443: Re-use or recycle hot or cold process exhaust air | $2,764 | $2,310 |
$2,764
26,084
kWh
|
|
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $878 | $860 |
$878
8,206
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,654 | $30,715 |
$12,654
116,354
kWh
|
|
| 05 | 2.7144: Install spectral reflectors / delamp | $21,143 | $16,440 |
$21,143
185,522
kWh
|
|
| 06 | 2.7135: Install occupancy sensors | $3,279 | $1,584 |
$3,279
28,722
kWh
|
|
| TOTAL RECOMMENDED | $46,865 | $51,909 |
$46,865
364,888
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs