ITAC Assessment: SD0104
ITAC logo
ITAC Assessment: SD0104
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Composite Materials
NAICS
n/a
SIC 3624: Carbon and Graphite Products
Sales Range $50
M
to 100
M
# of Employees 200
Plant Area 330,000
ft2
Annual Production 600,000
lb
Production Hrs. Annual 6,756
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $915,770 11,335,287
kWh
Natural Gas $186,890 49,990
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $161,893 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $63,447

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4133: Use most efficient type of electric motors $24,474 $22,100 $24,474
303,048
kWh
-
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,382 $9,800 $4,382
54,220
kWh
-
03 2.2449: Recover heat from exhausted steam, hot air or hot water $3,356 $3,400 - $3,356
-
MMBtu
04 2.2437: Recover waste heat from equipment $83,952 $150,000 - $83,952
-
MMBtu
05 2.2522: Isolate hot or cold equipment $890 - $890
21,395
kWh
-
06 2.6218: Turn off equipment when not in use $4,248 $3,000 $4,248
52,462
kWh
-
07 2.1222: Install turbulators $1,618 $1,600 - $1,618
-
MMBtu
08 2.7142: Utilize higher efficiency lamps and/or ballasts $25,523 $23,647 $25,523
296,014
kWh
-
09 2.7144: Install spectral reflectors / delamp $13,450 $17,980 $13,450
148,300
kWh
-
TOTAL RECOMMENDED $161,893 $231,527 $72,967
875,439
kWh
$88,926
-
MMBtu
TOTAL IMPLEMENTED $63,447 $63,727 $63,447
747,362
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings