Assessment Year | 1995 |
---|---|
Principal Product | Honeycomb Panels |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
76,000
ft2
|
Annual Production | 7,200,000
lb
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $118,408 | 1,002,931 |
kWh
|
$0.12 |
Natural Gas | $7,983 | 1,209 |
MMBtu
|
$6.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,016 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,016 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,634 | $1,990 |
$1,634
13,775
kWh
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $282 | $240 |
$282
2,345
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,448 | $2,812 |
$1,448
12,309
kWh
|
|
04 | 2.7144: Install spectral reflectors / delamp | $2,111 | $1,635 |
$2,111
16,706
kWh
|
|
05 | 2.7135: Install occupancy sensors | $713 | $591 |
$713
5,569
kWh
|
|
06 | 2.7134: Use photocell controls | $1,828 | $1,712 |
$1,828
15,533
kWh
|
|
TOTAL RECOMMENDED | $8,016 | $8,980 |
$8,016
66,237
kWh
|
||
TOTAL IMPLEMENTED | $8,016 | $8,980 |
$8,016
66,237
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs