Assessment Year | 1994 |
---|---|
Principal Product | Diagnostic Chemicals |
NAICS |
n/a
|
SIC | 2833: Medicinal Chemicals and Botanical Products |
Sales Range | $5 M to 10M |
# of Employees | 92 |
Plant Area |
59,630
ft2
|
Annual Production | 4,000
lb
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $193,652 | 2,474,209 |
kWh
|
$0.078 |
Natural Gas | $59,987 | 10,782 |
MMBtu
|
$5.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,538 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,020 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3112: Store heated/ cooled water for use during peak demand periods | $15,610 | $32,459 |
$15,610
-
kWh
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,808 | $5,000 |
$6,808
148,007
kWh
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $19,212 | $15,000 |
$19,212
419,402
kWh
|
|
04 | 2.7111: Reduce illumination to minimum necessary levels | $104 | $27 |
$104
879
kWh
|
|
05 | 2.7132: Install timers on light switches in little used areas | $1,627 | $225 |
$1,627
15,826
kWh
|
|
06 | 2.7135: Install occupancy sensors | $177 | $353 |
$177
2,052
kWh
|
|
TOTAL RECOMMENDED | $43,538 | $53,064 |
$43,538
586,166
kWh
|
||
TOTAL IMPLEMENTED | $26,020 | $20,000 |
$26,020
567,409
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs