Assessment Year | 1994 |
---|---|
Principal Product | Plastic Injection |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 80 |
Plant Area |
16,836
ft2
|
Annual Production | 11,000
lb
|
Production Hrs. Annual | 6,375
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $138,605 | 1,291,032 |
kWh
|
$0.11 |
Natural Gas | $1,486 | 168 |
MMBtu
|
$8.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,299 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,299 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $348 | $20 |
$348
4,396
kWh
|
|
02 | 2.2511: Insulate bare equipment | $593 | $334 |
$593
5,569
kWh
|
|
03 | 2.7132: Install timers on light switches in little used areas | $3,860 | $240 |
$3,860
33,411
kWh
|
|
04 | 2.7132: Install timers on light switches in little used areas | $147 | $75 |
$147
1,172
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $305 | $175 |
$305
1,465
kWh
|
|
06 | 2.3137: Use power during off-peak periods | $1,046 | - |
$1,046
-
kWh
|
|
TOTAL RECOMMENDED | $6,299 | $844 |
$6,299
46,013
kWh
|
||
TOTAL IMPLEMENTED | $6,299 | $844 |
$6,299
46,013
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs