Assessment Year | 1993 |
---|---|
Principal Product | COMPOSITE MATERIALS |
NAICS |
n/a
|
SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
n/a
|
Annual Production | 3,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $415,315 | 4,206,624 |
kWh
|
$0.099 |
Natural Gas | $261,331 | 51,825 |
MMBtu
|
$5.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $115,057 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,426 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,294 | $1,103 |
$1,294
13,189
kWh
|
- | |
02 | 2.2628: Utilize a less expensive cooling method | $82,299 | $143,700 |
$82,299
1,086,753
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,491 | - |
$2,711
27,550
kWh
|
$(-220.0) | |
04 | 2.7144: Install spectral reflectors / delamp | $18,758 | $17,100 |
$16,041
162,368
kWh
|
$2,717 | |
05 | 2.6232: Install set-back timers | $4,596 | $5,840 |
$4,032
40,739
kWh
|
$564 | |
06 | 2.6232: Install set-back timers | $3,841 | $1,600 |
$3,453
34,877
kWh
|
$388 | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,778 | - |
$2,300
23,447
kWh
|
$(-522.0) | |
TOTAL RECOMMENDED | $115,057 | $169,343 |
$112,130
1,388,923
kWh
|
$2,927 | ||
TOTAL IMPLEMENTED | $26,426 | $24,043 |
$23,667
239,743
kWh
|
$2,759 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs