ITAC Assessment: SD0007
ITAC logo
ITAC Assessment: SD0007
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1991
Principal Product WELDED TUBING
NAICS
n/a
SIC 3317: Steel Pipe and Tubes
Sales Range $5
M
to 10
M
# of Employees 65
Plant Area
n/a
Annual Production 250
thousand feet
Production Hrs. Annual 4,250
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $65,165 716,002
kWh
Natural Gas $23,176 3,837
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $5,867 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,867

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $223 $243 $223
2,345
kWh
- -
02 2.1131: Repair faulty insulation in furnaces, boilers, etc $1,105 $2,338 - $1,105
-
MMBtu
-
03 2.2514: Cover open tanks $1,377 $600 - $1,377
-
MMBtu
-
04 2.6232: Install set-back timers $464 $600 $244
2,345
kWh
- $220
05 2.7123: Keep lamps and reflectors clean $560 $660 $513
5,569
kWh
- $47
06 2.7123: Keep lamps and reflectors clean $1,864 $6,280 $1,679
18,464
kWh
- $185
07 2.7142: Utilize higher efficiency lamps and/or ballasts $213 $160 $137
1,465
kWh
- $76
08 2.7142: Utilize higher efficiency lamps and/or ballasts $61 $78 $61
586
kWh
- -
TOTAL RECOMMENDED $5,867 $10,959 $2,857
30,774
kWh
$2,482
-
MMBtu
$528
TOTAL IMPLEMENTED $5,867 $10,959 $2,857
30,774
kWh
$2,482
-
MMBtu
$528
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs