| Assessment Year | 2026 |
|---|---|
| Principal Product | CMP Slurries |
| NAICS | 325180: Other Basic Inorganic Chemical Manufacturing |
| SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 120 |
| Plant Area |
175,000
ft2
|
| Annual Production | 13,227,735
lb
|
| Production Hrs. Annual | 6,168
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $274,900 | 3,745,233 |
kWh
|
$0.073 |
| Electricity Demand | $156,898 | 8,054 |
kW-mo/yr
|
$19.48 |
| Electricity Fees | $21,414 | - |
|
- |
| Natural Gas | $35,521 | 2,802 |
MMBtu
|
$12.68 |
| TOTAL YEARLY COSTS | $488,733 | |||
| RECOMMENDED SAVINGS* | $120,640 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7132: Install timers on light switches in little used areas | $8,099 | $3,940 |
$8,099
110,344
kWh
|
- | |
| 02 | 2.6231: Utilize controls to operate equipment only when needed | $41,804 | $330,355 |
$41,804
569,531
kWh
|
- | |
| 03 | 2.9114: Use solar heat to make electricty | $70,737 | $992,750 |
$41,804
569,537
kWh
|
$28,933
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $120,640 | $1,327,045 |
$91,707
1,249,412
kWh
|
$28,933
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs