| Assessment Year | 2026 |
|---|---|
| Principal Product | aluminum extrusions |
| NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
| SIC | 3354: Aluminum Extruded Products |
| Sales Range | $10 M to 50M |
| # of Employees | 600 |
| Plant Area |
145,693
ft2
|
| Annual Production | 140,000
ton
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,463,034 | 20,207,920 |
kWh
|
$0.072 |
| Electricity Demand | $751,780 | 64,846 |
kW-mo/yr
|
$11.59 |
| Electricity Fees | $132,212 | - |
|
- |
| Natural Gas | $162,023 | 93,781 |
MMBtu
|
$1.73 |
| TOTAL YEARLY COSTS | $2,509,049 | |||
| RECOMMENDED SAVINGS* | $27,414 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,339 | $36,541 |
$6,019
83,132
kWh
|
$1,320
-
kW-mo/yr
|
- | - | |
| 02 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $3,864 | $121,611 | - | - | - |
$3,864
-
MMBtu
|
|
| 03 | 2.3212: Optimize plant power factor | $16,211 | $80,309 | - | - | $16,211 | - | |
| TOTAL RECOMMENDED | $27,414 | $238,461 |
$6,019
83,132
kWh
|
$1,320
-
kW-mo/yr
|
$16,211 |
$3,864
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs