| Assessment Year | 2025 |
|---|---|
| Principal Product | Aluminum Billets |
| NAICS | 331524: Aluminum Foundries (except Die-Casting) |
| SIC | 3365: Aluminum Foundries |
| Sales Range | $50 M to 100M |
| # of Employees | 72 |
| Plant Area |
249,000
ft2
|
| Annual Production | 105,000,000
lb
|
| Production Hrs. Annual | 8,280
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $322,875 | 9,474,400 |
kWh
|
$0.034 | |
| Electricity Demand | $138,670 | 19,810 |
kW-mo/yr
|
$7.00 | |
| Electricity Fees | $9,000 | - |
|
- | |
| Natural Gas | $634,990 | 239,758 |
MMBtu
|
$2.65 | |
| Waste Disposal Costs | |||||
| Water Usage | $5,901 | 1,644 |
Tgal
|
$3.59 | |
| TOTAL YEARLY COSTS | $1,111,436 | ||||
| RECOMMENDED SAVINGS* | $165,319 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2211: Use optimum temperature | $80,204 | $220 | - | - |
$80,204
-
MMBtu
|
|
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,031 | $626 |
$824
21,637
kWh
|
$207
-
kW-mo/yr
|
- | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $1,702 | $1,080 |
$1,702
44,669
kWh
|
- | - | |
| 04 | 2.9114: Use solar heat to make electricty | $82,382 | $1,300,527 |
$56,677
1,487,580
kWh
|
$25,705
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $165,319 | $1,302,453 |
$59,203
1,553,886
kWh
|
$25,912
-
kW-mo/yr
|
$80,204
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs