Assessment Year | 2024 |
---|---|
Principal Product | Treated Wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $5 M to 10M |
# of Employees | 7 |
Plant Area |
1,608,337
ft2
|
Annual Production | 839,500
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $84,261 | 1,004,378 |
kWh
|
$0.084 | |
Electricity Demand | $20,547 | 2,764 |
kW-mo/yr
|
$7.43 | |
Electricity Fees | $10,483 | - |
|
- | |
Natural Gas | $33,857 | 3,100 |
MMBtu
|
$10.92 | |
Waste Disposal Costs | |||||
Water Usage | $1 | 839,500 |
Tgal
|
$0.000 | |
TOTAL YEARLY COSTS | $149,149 | ||||
RECOMMENDED SAVINGS* | $66,895 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3322: Use existing dam to generate electricity | $4,211 | $17,825 |
$4,211
62,016
kWh
|
- | - | - | |
02 | 2.2443: Re-use or recycle hot or cold process exhaust air | $2,639 | $227 |
$2,639
31,454
kWh
|
- | - | - | |
03 | 4.463: Modify facility to avoid excess maintenance costs | $7,711 | $22,822 |
$191
2,282
kWh
|
- | $3,200 | $4,320 | |
04 | 3.1191: Change procedures / equipment / operating conditions | $3,405 | $16,073 |
$3,066
36,551
kWh
|
$339
-
kW-mo/yr
|
- | - | |
05 | 2.9121: Install wind powered electric generator | $5,114 | $43,821 |
$4,561
54,372
kWh
|
$553
-
kW-mo/yr
|
- | - | |
06 | 2.9114: Use solar heat to make electricty | $43,815 | $607,740 |
$37,841
451,033
kWh
|
$5,974
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $66,895 | $708,508 |
$52,509
637,708
kWh
|
$6,866
-
kW-mo/yr
|
$3,200 | $4,320 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs