| Assessment Year | 2023 |
|---|---|
| Principal Product | Aggregate |
| NAICS | 212321: Construction Sand and Gravel Mining |
| SIC | 1442: Construction Sand and Gravel |
| Sales Range | $10 M to 50M |
| # of Employees | 24 |
| Plant Area |
1,700,000
ft2
|
| Annual Production | 1,200,000
ton
|
| Production Hrs. Annual | 2,860
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $122,277 | 2,339,335 |
kWh
|
$0.052 |
| Electricity Demand | $156,890 | 13,810 |
kW-mo/yr
|
$11.36 |
| Electricity Fees | $1,034 | - |
|
- |
| Other Energy | $313,837 | 11,403 |
MMBtu
|
$27.52 |
| TOTAL YEARLY COSTS | $594,038 | |||
| RECOMMENDED SAVINGS* | $604,077 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $618 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Energy Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.1161: Eliminate/reduce an operation | $112,997 | $116,429 | - | - | - |
$40,363
-
MMBtu
|
$72,634 | |
| 02 | 2.3212: Optimize plant power factor | $3,665 | $20,839 | - | - | $3,665 | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $618 | $2,576 |
$618
11,815
kWh
|
- | - | - | - | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $486,797 | $4,030,000 |
$(-45,001.0)
(-860,937)
kWh
|
$(-61,021.0)
-
kW-mo/yr
|
- |
$150,352
-
MMBtu
|
$442,467 | |
| TOTAL RECOMMENDED | $604,077 | $4,169,844 |
$(-44,383.0)
(-849,122)
kWh
|
$(-61,021.0)
-
kW-mo/yr
|
$3,665 |
$190,715
-
MMBtu
|
$515,101 | ||
| TOTAL IMPLEMENTED | $618 | $2,576 |
$618
11,815
kWh
|
- | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs