Assessment Year | 2023 |
---|---|
Principal Product | Frozen Blueberrys |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
100,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 6,396
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $190,512 | 3,235,260 |
kWh
|
$0.059 |
Electricity Demand | $175,217 | 13,627 |
kW-mo/yr
|
$12.86 |
Electricity Fees | $31,773 | - |
|
- |
TOTAL YEARLY COSTS | $397,502 | |||
RECOMMENDED SAVINGS* | $177,246 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Primary Product Savings |
---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $174,406 | $233,000 |
$1,996
36,630
kWh
|
$172,410 | |
02 | 2.7135: Install occupancy sensors | $563 | $261 |
$563
10,333
kWh
|
- | |
03 | 2.9114: Use solar heat to make electricty | $2,277 | $41,745 |
$2,277
33,693
kWh
|
- | |
TOTAL RECOMMENDED | $177,246 | $275,006 |
$4,836
80,656
kWh
|
$172,410 | ||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs