| Assessment Year | 1996 |
|---|---|
| Principal Product | household lamps |
| NAICS |
n/a
|
| SIC | 3645: Residential Electric Lighting Fixtures |
| Sales Range | $5 M to 10M |
| # of Employees | 65 |
| Plant Area |
100,940
ft2
|
| Annual Production | 120,000
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $45,880 | 686,987 |
kWh
|
$0.067 |
| Electricity Fees | $(-2,648.0) | - |
|
- |
| Natural Gas | $40,220 | 8,327 |
MMBtu
|
$4.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,915 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $269 | - |
$303
7,034
kWh
|
$(-34.0) | - | - | - | - | - | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $699 | $441 |
$787
18,171
kWh
|
$(-88.0) | - | - | - | - | - | |
| 03 | 2.2437: Recover waste heat from equipment | $2,380 | $4,484 | - | - |
$2,230
-
MMBtu
|
$75
-
Tgal
|
- | - |
$75
-
Tgal
|
|
| 04 | 2.2437: Recover waste heat from equipment | $2,297 | $2,580 | - | - |
$2,297
-
MMBtu
|
- | - | - | - | |
| 05 | 3.7196: Use re-usable filters | $270 | $450 | - | - | - | - | - | $270 | - | |
| 06 | 3.5311: Recover and reuse waste material | $7,000 | $20,494 | - | - | - | - |
$7,000
-
lb
|
- | - | |
| TOTAL RECOMMENDED | $12,915 | $28,449 |
$1,090
25,205
kWh
|
$(-122.0) |
$4,527
-
MMBtu
|
$75
-
Tgal
|
$7,000
-
lb
|
$270 |
$75
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs