| Assessment Year | 2022 |
|---|---|
| Principal Product | Dimensional Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 59 |
| Plant Area |
45,000
ft2
|
| Annual Production | 24,000,000
units
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $171,566 | 3,901,955 |
kWh
|
$0.044 |
| Electricity Demand | $171,692 | 24,223 |
kW-mo/yr
|
$7.09 |
| Electricity Fees | $31,895 | - |
|
- |
| TOTAL YEARLY COSTS | $375,153 | |||
| RECOMMENDED SAVINGS* | $129,214 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $116,288 | - |
$676
14,703
kWh
|
$901
-
kW-mo/yr
|
- | $114,711 | |
| 02 | 2.3212: Optimize plant power factor | $9,428 | $38,054 | - | - | $9,428 | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,498 | - |
$1,499
32,614
kWh
|
$1,999
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $129,214 | $38,054 |
$2,175
47,317
kWh
|
$2,900
-
kW-mo/yr
|
$9,428 | $114,711 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs