Assessment Year | 2019 |
---|---|
Principal Product | Resonators |
NAICS | 333242: Semiconductor Machinery Manufacturing |
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $10 M to 50M |
# of Employees | 54 |
Plant Area |
14,000
ft2
|
Annual Production | 484
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,158 | 1,169,739 |
kWh
|
$0.076 |
Electricity Demand | $8,828 | 2,445 |
kW-mo/yr
|
$3.61 |
Electricity Fees | $14,166 | - |
|
- |
Natural Gas | $5,000 | 916 |
MMBtu
|
$5.46 |
TOTAL YEARLY COSTS | $117,152 | |||
RECOMMENDED SAVINGS* | $9,871 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,840 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,581 | $7,570 |
$4,113
56,808
kWh
|
$851
-
kW-mo/yr
|
- | $813 | $(-196.0) | |
02 | 2.7314: Reduce ventilation air | $1,259 | - |
$1,259
17,383
kWh
|
- | - | - | - | |
03 | 2.2437: Recover waste heat from equipment | $3,031 | $3,570 |
$156
2,156
kWh
|
- |
$2,875
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $9,871 | $11,140 |
$5,528
76,347
kWh
|
$851
-
kW-mo/yr
|
$2,875
-
MMBtu
|
$813 | $(-196.0) | ||
TOTAL IMPLEMENTED | $6,840 | $7,570 |
$5,372
74,191
kWh
|
$851
-
kW-mo/yr
|
- | $813 | $(-196.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs