| Assessment Year | 2019 |
|---|---|
| Principal Product | Resonators |
| NAICS | 333242: Semiconductor Machinery Manufacturing |
| SIC | 3674: Semiconductors and Related Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 54 |
| Plant Area |
14,000
ft2
|
| Annual Production | 484
units
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $89,158 | 1,169,739 |
kWh
|
$0.076 |
| Electricity Demand | $8,828 | 2,445 |
kW-mo/yr
|
$3.61 |
| Electricity Fees | $14,166 | - |
|
- |
| Natural Gas | $5,000 | 916 |
MMBtu
|
$5.46 |
| TOTAL YEARLY COSTS | $117,152 | |||
| RECOMMENDED SAVINGS* | $9,871 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,840 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,581 | $7,570 |
$4,113
56,808
kWh
|
$851
-
kW-mo/yr
|
- | $813 | $(-196.0) | |
| 02 | 2.7314: Reduce ventilation air | $1,259 | - |
$1,259
17,383
kWh
|
- | - | - | - | |
| 03 | 2.2437: Recover waste heat from equipment | $3,031 | $3,570 |
$156
2,156
kWh
|
- |
$2,875
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $9,871 | $11,140 |
$5,528
76,347
kWh
|
$851
-
kW-mo/yr
|
$2,875
-
MMBtu
|
$813 | $(-196.0) | ||
| TOTAL IMPLEMENTED | $6,840 | $7,570 |
$5,372
74,191
kWh
|
$851
-
kW-mo/yr
|
- | $813 | $(-196.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs