Assessment Year | 2017 |
---|---|
Principal Product | Fabricated Metal Structures |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $100 M to 500M |
# of Employees | 350 |
Plant Area |
2,309,000
ft2
|
Annual Production | 15
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $177,965 | 2,518,252 |
kWh
|
$0.071 |
Electricity Demand | $33,999 | 7,010 |
kW-mo/yr
|
$4.85 |
Electricity Fees | $10,856 | - |
|
- |
TOTAL YEARLY COSTS | $222,820 | |||
RECOMMENDED SAVINGS* | $30,736 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.5123: Reduce fluid flow rates | $26,801 | $7,395 |
$26,801
379,236
kWh
|
- | - | - | |
02 | 2.2628: Utilize a less expensive cooling method | $2,636 | $3,060 |
$136
1,921
kWh
|
- | - | $2,500 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,299 | $3,670 |
$700
9,899
kWh
|
$132
-
kW-mo/yr
|
$302 | $165 | |
TOTAL RECOMMENDED | $30,736 | $14,125 |
$27,637
391,056
kWh
|
$132
-
kW-mo/yr
|
$302 | $2,665 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs