Assessment Year | 2015 |
---|---|
Principal Product | Seafood |
NAICS | 311710: Seafood Product Preparation and Packaging |
SIC | 2077: Animal and Marine Fats and Oils |
Sales Range | $100 M to 500M |
# of Employees | 269 |
Plant Area |
210,000
ft2
|
Annual Production | 57,000,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $545,525 | 9,411,920 |
kWh
|
$0.058 |
Electricity Demand | $179,517 | 20,850 |
kW-mo/yr
|
$8.61 |
Electricity Fees | $66,824 | - |
|
- |
Natural Gas | $108,535 | 29,043 |
MMBtu
|
$3.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,303 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,510 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,705 | $20,000 |
$8,485
137,254
kWh
|
$2,423
-
kW-mo/yr
|
- | - | $726 | $(-929.0) | - | |
02 | 3.4131: Minimize contamination of water before treatment | $26,260 | $7,200 | - | - | - | - | $(-3,740.0) | - |
$30,000
-
Tgal
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $906 | $900 |
$906
14,663
kWh
|
- | - | - | - | - | - | |
04 | 2.2511: Insulate bare equipment | $6,192 | $8,000 |
$(-24.0)
(-382)
kWh
|
- | - |
$6,216
-
gal
|
- | - | - | |
05 | 2.1116: Improve combustion control capability | $4,259 | $5,617 |
$655
10,595
kWh
|
- |
$3,604
-
MMBtu
|
- | - | - | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,165 | $3,410 |
$6,165
99,723
kWh
|
- | - | - | - | - | - | |
07 | 2.2511: Insulate bare equipment | $1,353 | $8,000 | - | - |
$1,353
-
MMBtu
|
- | - | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,463 | - |
$1,154
18,669
kWh
|
$309
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $57,303 | $53,127 |
$17,341
280,522
kWh
|
$2,732
-
kW-mo/yr
|
$4,957
-
MMBtu
|
$6,216
-
gal
|
$(-3,014.0) | $(-929.0) |
$30,000
-
Tgal
|
||
TOTAL IMPLEMENTED | $44,510 | $43,200 |
$8,461
136,872
kWh
|
$2,423
-
kW-mo/yr
|
$1,353
-
MMBtu
|
$6,216
-
gal
|
$(-3,014.0) | $(-929.0) |
$30,000
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs