Assessment Year | 2014 |
---|---|
Principal Product | Machined Parts |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
45,000
ft2
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,801 | 1,593,853 |
kWh
|
$0.073 |
Electricity Demand | $21,696 | 4,114 |
kW-mo/yr
|
$5.27 |
Electricity Fees | $8,561 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,753 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $11,654 | $1,000 |
$11,654
140,394
kWh
|
- | |
02 | 2.2628: Utilize a less expensive cooling method | $5,751 | $5,908 |
$5,751
64,326
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,834 | $800 |
$3,834
42,883
kWh
|
- | |
04 | 2.9114: Use solar heat to make electricty | $5,889 | $72,131 |
$5,768
69,485
kWh
|
$121
-
kW-mo/yr
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,528 | - |
$4,956
55,422
kWh
|
$572
-
kW-mo/yr
|
|
06 | 2.5123: Reduce fluid flow rates | $2,097 | $5,600 |
$2,097
23,998
kWh
|
- | |
TOTAL RECOMMENDED | $34,753 | $85,439 |
$34,060
396,508
kWh
|
$693
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs