| Assessment Year | 2012 |
|---|---|
| Principal Product | Drywall Corner Trims |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
55,000
ft2
|
| Annual Production | 4,320,000
units
|
| Production Hrs. Annual | 1,800
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $97,717 | 1,707,000 |
kWh
|
$0.057 |
| Electricity Demand | $44,130 | 6,617 |
kW-mo/yr
|
$6.67 |
| Electricity Fees | $10,909 | - |
|
- |
| Natural Gas | $3,562 | 388 |
MMBtu
|
$9.18 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,144 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,865 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2628: Utilize a less expensive cooling method | $14,559 | $2,500 |
$11,012
187,814
kWh
|
$3,547
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,704 | $500 |
$943
16,087
kWh
|
$761
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $334 | - |
$334
5,688
kWh
|
- | - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $940 | $392 |
$565
9,640
kWh
|
$375
-
kW-mo/yr
|
- | - | - | |
| 05 | 4.622: Install rotating carousels to reduce set-up times | $4,720 | - |
$(-334.0)
(-5,702)
kWh
|
- | - | - | $5,054 | |
| 06 | 2.2223: Enhance sensitivity of temperature control and cutoff | $6,653 | $385 | - | - | - | - | $6,653 | |
| 07 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,399 | $560 |
$5,299
90,381
kWh
|
- | $(-3,900.0) | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,835 | $2,724 |
$3,694
63,013
kWh
|
$531
-
kW-mo/yr
|
$146 | $464 | - | |
| TOTAL RECOMMENDED | $35,144 | $7,061 |
$21,513
366,921
kWh
|
$5,214
-
kW-mo/yr
|
$(-3,754.0) | $464 | $11,707 | ||
| TOTAL IMPLEMENTED | $15,865 | $4,561 |
$10,835
184,809
kWh
|
$1,667
-
kW-mo/yr
|
$(-3,754.0) | $464 | $6,653 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs