Assessment Year | 2012 |
---|---|
Principal Product | Fish |
NAICS | 424420: Packaged Frozen Food Merchant Wholesalers |
SIC | 2092: Prepared Fresh or Frozen Fish and Seafoods |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
60,000
ft2
|
Annual Production | 32,000,000
units
|
Production Hrs. Annual | 6,300
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $150,258 | 2,323,716 |
kWh
|
$0.065 |
Electricity Demand | $21,646 | 5,582 |
kW-mo/yr
|
$3.88 |
Electricity Fees | $9,662 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,714 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,328 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,611 | $12,467 |
$7,856
117,858
kWh
|
$933
-
kW-mo/yr
|
- | - | $91 | $(-1,269.0) | |
02 | 4.441: Install automatic packing equipment | $35,308 | - |
$(-756.0)
(-11,539)
kWh
|
- | - | $36,064 | - | - | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $1,422 | - |
$(-1,089.0)
(-16,489)
kWh
|
$(-754.0)
-
kW-mo/yr
|
$3,265
-
MMBtu
|
- | - | - | |
04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $1,409 | - |
$1,409
21,346
kWh
|
- | - | - | - | - | |
05 | 2.9114: Use solar heat to make electricty | $1,964 | $17,576 |
$1,904
28,827
kWh
|
$60
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $47,714 | $30,043 |
$9,324
140,003
kWh
|
$239
-
kW-mo/yr
|
$3,265
-
MMBtu
|
$36,064 | $91 | $(-1,269.0) | ||
TOTAL IMPLEMENTED | $44,328 | $12,467 |
$8,509
127,665
kWh
|
$933
-
kW-mo/yr
|
- | $36,064 | $91 | $(-1,269.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs