Assessment Year | 2012 |
---|---|
Principal Product | Wood Windows and Doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $50 M to 100M |
# of Employees | 275 |
Plant Area |
317,000
ft2
|
Annual Production | 65,000
pieces
|
Production Hrs. Annual | 3,328
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $291,898 | 5,604,052 |
kWh
|
$0.052 |
Electricity Demand | $124,323 | 19,398 |
kW-mo/yr
|
$6.41 |
Electricity Fees | $35,517 | - |
|
- |
Natural Gas | $62,384 | 13,315 |
MMBtu
|
$4.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,279 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,137 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4131: Size electric motors for peak operating efficiency | $5,954 | $5,038 |
$4,016
74,608
kWh
|
$1,938
-
kW-mo/yr
|
- | - | - | |
02 | 2.2211: Use optimum temperature | $3,137 | - | - | - |
$3,137
-
MMBtu
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,188 | $87,787 |
$13,627
249,128
kWh
|
$4,719
-
kW-mo/yr
|
- | $(-506.0) | $348 | |
TOTAL RECOMMENDED | $27,279 | $92,825 |
$17,643
323,736
kWh
|
$6,657
-
kW-mo/yr
|
$3,137
-
MMBtu
|
$(-506.0) | $348 | ||
TOTAL IMPLEMENTED | $3,137 | - | - | - |
$3,137
-
MMBtu
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs