| Assessment Year | 2012 |
|---|---|
| Principal Product | Wood Millwork for Doors and Windows |
| NAICS | 321918: Other Millwork (including Flooring) |
| SIC | 5031: Lumber, Plywood, Millwork, and Wood Panels |
| Sales Range | $10 M to 50M |
| # of Employees | 145 |
| Plant Area |
304,000
ft2
|
| Annual Production | 9,053
thousand feet
|
| Production Hrs. Annual | 5,500
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $437,847 | 8,406,079 |
kWh
|
$0.052 |
| Electricity Demand | $186,484 | 29,096 |
kW-mo/yr
|
$6.41 |
| Electricity Fees | $8,818 | - |
|
- |
| Natural Gas | $93,577 | 19,972 |
MMBtu
|
$4.69 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,948 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,534 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,386 | - | - |
$2,386
-
kW-mo/yr
|
- | - | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,711 | $6,200 |
$4,326
80,363
kWh
|
$1,385
-
kW-mo/yr
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,823 | $53,151 |
$8,825
161,340
kWh
|
$2,263
-
kW-mo/yr
|
$243 | $1,492 | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $25,028 | $43,292 |
$18,563
344,805
kWh
|
$6,465
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $45,948 | $102,643 |
$31,714
586,508
kWh
|
$12,499
-
kW-mo/yr
|
$243 | $1,492 | ||
| TOTAL IMPLEMENTED | $18,534 | $59,351 |
$13,151
241,703
kWh
|
$3,648
-
kW-mo/yr
|
$243 | $1,492 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs