Assessment Year | 2011 |
---|---|
Principal Product | Fiber Board Door Skins |
NAICS | 321999: All Other Miscellaneous Wood Product Manufacturing |
SIC | 2493: Reconstituted Wood Products |
Sales Range | $10 M to 50M |
# of Employees | 64 |
Plant Area |
98,700
ft2
|
Annual Production | 6,365,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,056,873 | 22,787,659 |
kWh
|
$0.046 |
Electricity Demand | $249,019 | 46,808 |
kW-mo/yr
|
$5.32 |
Electricity Fees | $1,757 | - |
|
- |
Natural Gas | $206,891 | 40,925 |
MMBtu
|
$5.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,392 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,137 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $1,800 | - |
$1,800
38,700
kWh
|
- | - | - | - | |
02 | 2.1113: Reduce combustion air flow to optimum | $7,781 | $500 | - |
$7,781
-
MMBtu
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,748 | $3,023 |
$2,748
56,905
kWh
|
- | - | - | - | |
04 | 2.2136: Install / repair insulation on steam lines | $3,389 | $948 | - | - |
$3,389
-
MMBtu
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $8,400 | $7,692 |
$8,400
173,200
kWh
|
- | - | - | - | |
06 | 2.1113: Reduce combustion air flow to optimum | $3,994 | $16,460 | - |
$3,994
-
MMBtu
|
- | - | - | |
07 | 2.7135: Install occupancy sensors | $4,280 | $2,630 |
$3,030
65,652
kWh
|
- | - | $300 | $950 | |
TOTAL RECOMMENDED | $32,392 | $31,252 |
$15,978
334,457
kWh
|
$11,775
-
MMBtu
|
$3,389
-
MMBtu
|
$300 | $950 | ||
TOTAL IMPLEMENTED | $6,137 | $3,970 |
$2,748
56,905
kWh
|
- |
$3,389
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs