Assessment Year | 2011 |
---|---|
Principal Product | Dry Veneer |
NAICS | 321212: Softwood Veneer and Plywood Manufacturing |
SIC | 2436: Softwood Veneer and Plywood |
Sales Range | $10 M to 50M |
# of Employees | 62 |
Plant Area |
110,000
ft2
|
Annual Production | 10,017,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $192,679 | 4,517,200 |
kWh
|
$0.043 |
Electricity Demand | $57,119 | 11,516 |
kW-mo/yr
|
$4.96 |
Natural Gas | $416,494 | 83,996 |
MMBtu
|
$4.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,248 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.114: Add/modify equipment to improve drying process | $2,000 | $1,510 | - | - | - | $90 | - | $1,910 | |
02 | 2.7243: Improve air circulation with destratification fans / other methods | $8,491 | $8,300 |
$6,663
140,908
kWh
|
$1,828
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7135: Install occupancy sensors | $878 | $737 |
$606
12,826
kWh
|
- | - | - | $272 | - | |
04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $2,800 | $6,700 |
$2,800
59,200
kWh
|
- | - | - | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $12,000 | $5,580 |
$9,068
182,711
kWh
|
$2,932
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.2511: Insulate bare equipment | $1,248 | $2,547 | - | - |
$1,248
-
MMBtu
|
- | - | - | |
07 | 3.1161: Eliminate/reduce an operation | $17,603 | $2,480 |
$17,603
372,284
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $45,020 | $27,854 |
$36,740
767,929
kWh
|
$4,760
-
kW-mo/yr
|
$1,248
-
MMBtu
|
$90 | $272 | $1,910 | ||
TOTAL IMPLEMENTED | $15,248 | $9,637 |
$9,068
182,711
kWh
|
$2,932
-
kW-mo/yr
|
$1,248
-
MMBtu
|
$90 | - | $1,910 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs