Assessment Year | 2011 |
---|---|
Principal Product | Manufactured Homes |
NAICS | 321992: Prefabricated Wood Building Manufacturing |
SIC | 2451: Mobile Homes |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
150,000
ft2
|
Annual Production | 520
pieces
|
Production Hrs. Annual | 2,150
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $73,605 | 1,080,081 |
kWh
|
$0.068 |
Electricity Demand | $21,980 | 4,544 |
kW-mo/yr
|
$4.84 |
Electricity Fees | $4,585 | - |
|
- |
Natural Gas | $6,180 | 611 |
MMBtu
|
$10.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,080 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,260 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $3,230 | $635 |
$3,230
46,400
kWh
|
|
02 | 2.7135: Install occupancy sensors | $4,340 | $9,990 |
$4,340
45,600
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,690 | $1,690 |
$1,690
17,161
kWh
|
|
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $8,620 | $37,500 |
$8,620
124,000
kWh
|
|
05 | 2.9114: Use solar heat to make electricty | $15,200 | $146,000 |
$15,200
198,000
kWh
|
|
TOTAL RECOMMENDED | $33,080 | $195,815 |
$33,080
431,161
kWh
|
||
TOTAL IMPLEMENTED | $9,260 | $12,315 |
$9,260
109,161
kWh
|